How to Convert VMware Virtual Machines to XenServer Virtual Machines
How to Convert VMware Virtual Machines to XenServer Virtual Machines
•March 1, 2009 • Leave a CommentInstalling Citrix SmartAuditor Administration 1.1.1064
•January 16, 2009 • Leave a Comment
While installing the Citrix SmartAuditor Administration i’ll get the following error:

Workaround
To work around this problem, modify the registry to increase the default time-out value for the service control manager. To increase this value to 60 seconds, follow these steps:
- Click Start, click Run, type regedit, and then click OK.
- Locate and then click the following registry subkey:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
- In the right pane, locate the ServicesPipeTimeout entry.
Note If the ServicesPipeTimeout entry does not exist, you must create it. To do this, follow these steps:
- On the Edit menu, point to New, and then click DWORD Value.
- Type ServicesPipeTimeout, and then press ENTER.
- Right-click ServicesPipeTimeout, and then click Modify.
- Click Decimal, type 300000, and then click OK.
This value represents the time in milliseconds before a service times out.
- Restart the computer.
Note This workaround may resolve the problem where the service does not start. However, we recommend that you research this problem to determine whether it is a symptom of another problem.
Citrix Access Gateway Enterprise Edition Port Configuration
•December 11, 2008 • Leave a CommentCitrix Access Gateway Enterprise Edition Port Configuration
You already have an instance of this application open
•November 14, 2008 • Leave a CommentAccess is denied while running gpresult
•November 7, 2008 • Leave a CommentWhen u’r logged on with a domain administrator or local administrator u get “Access is Denied” while running gpresult.
Windows 2003 R2 SP2 Enterprise Server
Citrix Provisioning Server 4.5
Vdisk
The solution is:
Start within a prompt:
Regsvr32 /n /I c:\winnt\system32\userenv.dll
(From c:\windows\system32\wbem)
Mofcomp scersop.mof
Gpupdate /force
Source: http://www.techreplies.com/windows-server-60/running-gpresult-access-denied-message-747196/
Another Citrix & SBC site
•October 6, 2008 • 1 CommentJust found another Citrix & SBC site,while checking my stats.
Take a loot at http://digipulse.nl/
Provisioning Server 4.5 Service Pack 2
•October 6, 2008 • Leave a CommentCitrix is pleased to announce the release of Provisioning Server 4.5 Service Pack 2.
The following problem fixes and enhancements are in this release:
- • Added logging capabilities to the Stream process.
• Addressed a number of compatibility issues with BDM ISO and VMWare 3.5.
• Addressed problems with Network Interface Card (NIC) failover support when using standard image mode. By default the NIC failover feature is disabled, refer to the Service Pack 2 Release notes for instructions on how to enable this feature.
• Addressed a number of other product defects as described in the Service Pack 2 Release Notes.
Citrix recommends that customers review CTX118591– Citrix Provisioning Server 4.5 SP2 Release Notes for a more detailed overview of these changes before downloading and installing the product update
XenAppPrep Soon To Be Released
•September 23, 2008 • Leave a CommentXenApp registry editing “RadeRunSwitches”
•September 21, 2008 • Leave a CommentIf you have trouble with streaming application, you can use the RadeRun Switches.
For example:
If an application needs an component that isn’t their at pre-streaming you can use the option.
-e
Go to:
My Computer\HKEY_LOCAL_MACHINE\SOFTWARE\Citrix\Rade
Add an REG_SZ with the name RadeRunSwitches
The value you can use:
List of RadeRun Switches that can be placed in the registry:
-c clear the execution cache before the application opens
-C clear the execution cache and per-user cache before the application opens
-d clear the execution cache after the application terminates
-D clear the execution cache and per-user cache after the application terminates
-x execute a command prompt for every launched application (This is useful for debugging.)
-e pre-streams all files for the application to the client. (This pre-streams all application files instead of just the files that are needed at execution time. This is used when all components of an application are needed before the application can start).
Note: Adding the -e switch uses a larger amount of space on the client hard drive because all applications that the user has access to are pre-streamed and not just a particular application.ed applications
Citrix XenApp Comparative Feature Matrix
•September 6, 2008 • Leave a CommentYou can find the matrix of XenApp 5 below: